When Auto check box is selected, Adjustable Parameter will be determined by the Peak Analyzer automatically. Specify the value of adjustable parameter. It is available only when Adjustable Parameter is selected in Option dropdown list. If you want to specify Final Height manually, uncheck Auto. When Auto check box is selected, Final Height will be determined by the Peak Analyzer automatically. And it is also used to adjust the baseline. This specifies the Y value of the user-specified ending data point (baseline has been subtracted). Adjustable Parameter: Specify the value of the parameter which can be used to affect the creation of the baseline.Final Height: This value is used to set the Y value of the user-specified ending data point (baseline has been subtracted).Specifies a method to adjust the parameters which are related to create baseline. This is available only when the Method drop-down list is set to Tougaard. For more information, see Peak Analyzer Algorithms. When the Auto check box is selected, Energy(X) 2 will be determined by the Peak Analyzer automatically and Energy value is Read Only. It specifies the ending energy value(or x value) of the computation range. This is available only when Energy is selected in the Range drop-downlist. When the Auto check box is selected, Energy(X) 1 will be determined by the Peak Analyzer automatically and Energy value is Read Only. It specifies the starting energy value(or x value) of the computation range. This is available only when Energy is selected in the Range drop-down list. When the Auto check box is selected, Row2 will be determined by the Peak Analyzer automatically and Row value is Read Only. It specifies the ending row index of the computation range. This is available only when Row is selected in the Range drop-down list. When the Auto check box is selected, Row1 will be determined by the Peak Analyzer automatically and Row value is Read Only. It specifies the starting row index of the computation range. Energy can be viewed as the x values of the spectrum data. Energy: Specify the computation range by the energy values of the spectrum data.Row: Specify the computation range by the row indices of the spectrum data points.Specify a method to set the computation range of the spectrum data. The Computation Range Group Controls Range Menu Command: Analysis: Peaks and Baseline: Peak Analyzer: Open Dialog.This allows creating a special X-Ray photoemission spectrum baseline. This page is added to the Peak Analyzer when Baseline Mode is set to XPS.